Description:
The suspension composite insulator for electrified railway contact net consists of three parts: a mandrel, an outer insulation and a metal attachment. It shall comply with the standard of TB/T3199.2-2008 《Insulators for electrified railway contact nets - Part 2: Rod composite insulators》.
It can be widely used in areas with different pollution levels, with light weight, small volume, not easy to break, high tensile strength and strong pollution resistance.
Composite insulator for tunnel positioning (1):
Type
|
Rated voltage
(kV)
|
Rated bending load
(KN)
|
Structure height
(mm)
|
Insulation distance
(mm)
|
Min nominal creepage distance
(mm)
|
Lightning full wave impulse withstand voltage
(kV)
|
Power frequency dry withstand voltage
(kV)
|
Frequency withstand voltage
≥((kV))
|
IMG
|
FQD-25/20-BY-A1
|
25
|
20
|
750
|
490
|
1250
|
330
|
195
|
165
|
T-X
|
FQD-25/20-BY-A2
|
25
|
20
|
820
|
560
|
1600
|
360
|
210
|
180
|
T-X
|
|
Composite insulator for tunnel positioning (2):
Type
|
Rated voltage
(kV)
|
Rated bending load
(KN)
|
Structure height
(mm)
|
Insulation distance
(mm)
|
Min nominal creepage distance
(mm)
|
Lightning full wave impulse withstand voltage
(kV)
|
Power frequency dry withstand voltage
(kV)
|
Frequency withstand voltage
≥((kV))
|
IMG
|
FQD-25/20-EB-1
|
25
|
20
|
685
|
465
|
1200
|
300
|
180
|
150
|
T-X
|
FQD-25/20-EB-2
|
25
|
20
|
800
|
580
|
1600
|
360
|
210
|
180
|
T-X
|
|
Composite insulator for tunnel positioning (3):
Type
|
Rated voltage
(kV)
|
Rated bending load
(KN)
|
Structure height
(mm)
|
Insulation distance
(mm)
|
Min nominal creepage distance
(mm)
|
Lightning full wave impulse withstand voltage
(kV)
|
Power frequency dry withstand voltage
(kV)
|
Frequency withstand voltage
≥((kV))
|
IMG
|
FQD-25/20-EY-C1
|
25
|
20
|
1380
|
600
|
1400
|
300
|
180
|
150
|
T-X
|
FQD-25/20-EY-C2
|
25
|
20
|
1450
|
700
|
1600
|
360
|
210
|
180
|