Porcelain Pillar Drop-Out Fuse Types Power Line & Transformer Overload Protection Fuse

Classification:Fuse series

Inside Road & Administration Industry & Trading Garden,Houshan Industry Area,Fuzhou City,Fujian Province

0591-22806687 0591-22806697

0591-22806667

bs@china-grid.com.cn

Overview
Description:

The fuse is composed of two parts: the base and the arc extinguishing device. The lower end of the arc extinguishing tube is equipped with a spring bracket that can rotate, and the fuse is always in tension to ensure the self-locking of the arc extinguishing tube in the closing position.

In the overload or short circuit of the line and the transformer, the fuse is blown, the fuse is quickly extracted from the arc extinguishing tube, and the arc extinguishing tube is designed to solve the contradiction of breaking the current on the same fuse by the stepwise exhaust type.

Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
HRW10-10F/100 12 100 6.3 110 42 300 7.8 48×12×31
HRW10-10F/200 12 200 12.5 110 42 300 7.8
Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
RW10-10F/100 12 100 6.3 110 42 300 7.5 53×32×12
RW10-10F/200 12 200 12.5 110 42 300 7.5
Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
RW7-10/100 10 100 6.3 110 42 300 6.2 48×27×12
RW7-10/200 10 200 12.5 110 42 300 6.2
Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
RW3-10/100 10 100 6.3 110 42 300 6.2 48×27×12
RW3-10/200 10 200 12.5 110 42 300 6.2
Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
PRWG1-10/100 12 100 6.3 110 42 380 8.8 61X13X42
PRWG1-10/200 12 200 12.5 110 42 380 8.8

PRWG1 drop-out fuse has a large creepage distance and is highly resistant to dirt. It is suitable for use in altitudes or dirty areas.

Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
PRW-4 33 100 6.3 175 70 720 17 68X17X15
PRW-4 33 200 12.5 175 70 720 18
Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
PRW-12/100 12 100 6.3 100 42 320 4 47X40X12
PRW-12/100 12 200 12.5 110 42 320 5 47X40X12
Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
HPRWG2-35/100 35 100 6.3 170 70 1100 14 81X42X13
HPRWG2-35/200 35 200 12.5 170 70 1100 15 81X42X13
Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
PRWG2-35/100 35 100 6.3 170 70 800 21 87X34X165
PRWG2-35/200 35 200 12.5 170 70 800 22 87X34X165
Type Rated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
impulse voltage
(BIL)
Power frequency withstand voltage
(kV)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
HRW10-35F/100 35 100 6.3 170 70 1100 14 94×42×16
HRW10-35F/200 35 200 8.0 170 70 1100 15 94×42×16
Type Rated voltage
(kV)
Rated current
(A)
Three-phase breaking current capacity
(MVA)
Power frequency withstand voltage
(kV)
Power frequency wet withstand voltage
(KV)
Allowable temperature rise °C
(Except for the conductive part on the fuse tube)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
Upper limit Lower limit
HRW5-35/100 35 100 400 10 105 185 60 1000 23 87x71x15
HRW5-35/200 35 200 800 30 105 185 60 1000 23 87x71x15
Type Rated voltage
(kV)
Rated current
(A)
Three-phase breaking current capacity
(MVA)
Power frequency withstand voltage
(kV)
Power frequency wet withstand voltage
(KV)
Allowable temperature rise °C
(Except for the conductive part on the fuse tube)
Creepage distance
(mm)
Weight
(kg)
Outline size
(cm)
Upper limit Lower limit
RW5-35/100 35 100 400 10 105 185 60 650 21 87x71x15
RW5-35/200 35 200 800 30 105 185 60 650 22 87x71x15